Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC/LSZH
3. Identification:
Black Cores with White Number
1pc Green/Yellow Core
4. Screen: Tinned Copper Wire Braided
5. Sheath: PVC/LSZH (Grey)
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Rated Voltage: 300/300V
Reference Standards
BS6500
BS EN 60228
BS EN 50525-2-11
BS EN 50363-3
BS EN 50363-7
BS EN 50363-4-1
BS EN 50363-8
RoHS Directives
IEC60332-1
0.5mm2
|
Part No. |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.6 |
39 |
|
CY 3×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.9 |
39 |
|
CY 4×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
39 |
|
CY 5×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
39 |
|
CY 7×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
39 |
|
CY 8×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
8 |
39 |
|
CY 10×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
0.6 |
39 |
|
CY 12×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
9.9 |
39 |
|
CY 16×0.5 |
16/0.20 |
0.4 |
1.1 |
TC Braided |
11 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6 |
26 |
|
CY 3×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
26 |
|
CY 4×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
26 |
|
CY 5×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
7.33 |
26 |
|
CY 7×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
26 |
|
CY 8×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
26 |
|
CY 10×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
10.2 |
26 |
|
CY 12×0.75 |
24/0.20 |
0.4 |
1 |
TC Braided |
10.8 |
26 |
|
CY 16×0.75 |
24/0.20 |
0.4 |
1.1 |
TC Braided |
12 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.4 |
19.5 |
|
CY 3×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
19.5 |
|
CY 4×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
19.5 |
|
CY 5×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
19.5 |
|
CY 7×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
19.5 |
|
CY 8×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
9.8 |
19.5 |
|
CY 10×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
11.2 |
19.5 |
|
CY 12×1.0 |
32/0.20 |
0.4 |
1.1 |
TC Braided |
11.7 |
19.5 |
|
CY 16×1.0 |
32/0.20 |
0.4 |
1.2 |
TC Braided |
13.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7 |
13.3 |
|
CY 3×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7.4 |
13.3 |
|
CY 4×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
8.2 |
13.3 |
|
CY 5×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
9.1 |
13.3 |
|
CY 7×1.5 |
30/0.25 |
0.4 |
1 |
TC Braided |
10 |
13.3 |
|
CY 8×1.5 |
30/0.25 |
0.4 |
1.1 |
TC Braided |
11 |
13.3 |
|
CY 10×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
12.8 |
13.3 |
|
CY 12×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
13.2 |
13.3 |
|
CY 16×1.5 |
30/0.25 |
0.4 |
1.3 |
TC Braided |
14.7 |
13.3 |
2.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
8.2 |
7.98 |
|
CY 3×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
9.1 |
7.98 |
|
CY 4×2.5 |
48/0.25 |
0.5 |
1 |
TC Braided |
10.1 |
7.98 |
|
CY 5×2.5 |
48/0.25 |
0.5 |
1.1 |
TC Braided |
11.1 |
7.98 |
|
CY 7×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.2 |
7.98 |
|
CY 8×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.8 |
7.98 |
|
CY 10×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15 |
7.98 |
|
CY 12×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15.6 |
7.98 |
|
CY 16×2.5 |
48/0.25 |
0.5 |
1.4 |
TC Braided |
17.3 |
7.98 |
4.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 3×4.0 |
56/0.30 |
0.6 |
1.1 |
TC Braided |
11.4 |
4.95 |
|
CY 4×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
12.4 |
4.95 |
|
CY 5×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
13.5 |
4.95 |
|
CY 7×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
14.8 |
4.95 |
|
CY 8×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
16.0 |
4.95 |
Product detail pictures:
Related Product Guide:
Our concentrate on is always to consolidate and enhance the excellent and service of present solutions, in the meantime regularly develop new products to meet distinctive customers' demands for Short Lead Time For Shielded Signal Cable - CY Screened Multicore Control Cable – AIPU , The product will supply to all over the world, such as: Victoria, Borussia Dortmund, Nepal, Ensuring high product quality by choosing the best suppliers, we have also implemented comprehensive quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.
Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.