Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
|
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
|
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
|
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
|
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
|
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
|
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
|
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
|
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
|
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
|
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
|
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
|
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
|
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
|
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
|
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
|
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
|
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
|
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
|
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
|
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
|
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
|
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
|
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
|
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
|
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
|
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
|
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
|
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
|
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
|
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
|
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
|
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
|
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
|
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
|
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
|
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
|
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
|
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
|
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
|
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
|
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
|
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
|
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
|
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
|
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
|
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
|
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Stuttgart, luzern, France, Now, we professionally supplies customers with our main merchandise And our business is not only the "buy" and "sell", but also focus on more. We target to be your loyal supplier and long-term cooperator in China. Now, We hope to be the friends with you.
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.