Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
|
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
|
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
|
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
|
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
|
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
|
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
|
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
|
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
|
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
|
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
|
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
|
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
|
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
|
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
|
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
|
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
|
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
|
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
|
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
|
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
|
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
|
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
|
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
|
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
|
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
|
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
|
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
|
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
|
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
|
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
|
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
|
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
|
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
|
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
|
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
|
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
|
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
|
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
|
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
|
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
|
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
|
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
|
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
|
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
|
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
|
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
|
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
Our company promises all buyers of the first-class products and solutions as well as most satisfying post-sale support. We warmly welcome our regular and new shoppers to join us for Reasonable Price For Data Center Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Burundi, Mauritania, Bangalore, We have got constantly insisted on the evolution of solutions, spent good funds and human resource in technological upgrading, and facilitate production improvement, meeting the wants of prospects from all countries and regions.
Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.