abide by the contract", conforms on the market requirement, joins within the market competition by its superior quality likewise as provides far more comprehensive and great company for shoppers to let them develop into huge winner. The pursue on the corporation, is definitely the clients' gratification for Data Center Rack Space, Intercom Cable, Signal Cable Connector, "Passion, Honesty, Sound services, Keen cooperation and Development" are our goals. We've been here expecting close friends all around the earth!
Manufacturing Companies For Heat Trace Cable - Multicore Speaker Cable For Commercial Infrastructure – AIPU Detail:

Application

1. The cable is designed for loudspeaker application. It could be used for car audio, home HiFi, cinema, or speaker system with high-end cables for an unforgettable sound experience.
2. The three key electrical characteristics of a speaker cable are resistance, capacitance, and inductance. Of these, resistance is the most important. The speaker cable is the wire that connects the speaker to the amplifier source. 
3. The resistance of loudspeaker is mainly affected by conductor length and conductor cross-sectional area. The shorter the conductor, the lower the resistance, so reduce the length of the wire as much as possible, and place the speakers as far apart as possible, and the two speakers have the same lead length, so that they have the same impedance value. The larger the cross-sectional area of a conductor, the smaller the resistance.
4. Copper is the most suitable material for conductor according to cost and resistance. Apro’s speaker wire is also a pure copper conductor. Insulation is PO material or low smoke halogen free.

Constructions

1. Conductor: Stranded Oxygen Free Copper
2. Insulation: Polyolefin
3. Cabling: Cores laying-up
4. Sheath: PVC/LSZH

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

BS EN 60228
BS EN 50290
RoHS Directives
IEC60332-1

Identification of Insulation

Operating Voltage

300V

Test Voltage

1.0 KVdc

Conductor DCR

13.3 Ω/km  (Max. @ 20°C) for 1.5mm2

7.98 Ω/km  (Max. @ 20°C) for 2.5mm2

4.95 Ω/km  (Max. @ 20°C) for 4.0mm2

Insulation Resistance

200 MΩhms/km (Min.)

Part No.

Conductor Construction

Insulation

Sheath

Material

Size

AP70045

OFC

2×1.5mm2

LSZH

LSZH

AP70046

OFC

2×2.5mm2

LSZH

LSZH

AP70047

OFC

4×2.5mm2

LSZH

LSZH

AP70048

OFC

2×4.0mm2

LSZH

LSZH

AP1307A

OFC

2x16AWG

Polyolefin

PVC

AP1308A

OFC

4x16AWG

Polyolefin

PVC

AP1309A

OFC

2x14AWG

Polyolefin

PVC

AP1310A

OFC

4x14AWG

Polyolefin

PVC

AP1311A

OFC

2x12AWG

Polyolefin

PVC

AP1312A

OFC

2x16AWG

Polyolefin

PVC


Product detail pictures:

Manufacturing Companies For Heat Trace Cable - Multicore Speaker Cable For Commercial Infrastructure  – AIPU detail pictures

Manufacturing Companies For Heat Trace Cable - Multicore Speaker Cable For Commercial Infrastructure  – AIPU detail pictures

Manufacturing Companies For Heat Trace Cable - Multicore Speaker Cable For Commercial Infrastructure  – AIPU detail pictures


Related Product Guide:

As for aggressive costs, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such high-quality at such rates we have been the lowest around for Manufacturing Companies For Heat Trace Cable - Multicore Speaker Cable For Commercial Infrastructure – AIPU , The product will supply to all over the world, such as: Guatemala, Germany, Indonesia, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world
  • This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Dolores from Qatar - 2018.12.05 13:53
    The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Penelope from Barbados - 2017.04.28 15:45
    Write your message here and send it to us