Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
|
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
|
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
|
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
|
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
|
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
|
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
|
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
|
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
|
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
|
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
|
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
|
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
|
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
|
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
|
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
|
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
|
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
|
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
|
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
|
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
|
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
|
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
|
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
|
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
|
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
|
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
|
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
|
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
|
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
|
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
|
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
|
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
|
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
|
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
|
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
|
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
|
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
|
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
|
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
|
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
|
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
|
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
|
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
|
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
|
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
|
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
|
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for Manufacturer For Outdoor Network Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Georgia, Mecca, Burundi, "Good quality and reasonable price" are our business principles. If you are interested in our products or have any questions, please feel free to contact us. We hope to establish cooperative relationships with you in the near future.
Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!