Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:


Related Product Guide:
Our staff through skilled training. Skilled skilled knowledge, potent sense of company, to satisfy the provider requirements of consumers for Manufacturer For Outdoor Network Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Colombia, America, Swansea, We've got constantly insisted on the evolution of solutions, spent good funds and human resource in technological upgrading, and facilitate production improvement, meeting the wants of prospects from all countries and regions.