Adhering for the theory of "quality, services, performance and growth", we have received trusts and praises from domestic and worldwide shopper for Control Cable Wire, Dust Proof Server Rack, Lszh Cat5e Cable, We are sincere and open. We look forward to your visit and establishing trustworthy and long-term standing relationship.
Low Price For Speaker Cable - LiHH Multicore Control Cable (Halogen Free) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
5. Sheath: LSZH

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.14

12/0.12

0.3

0.6

3.4

148

LiHH 3×0.14

12/0.12

0.3

0.6

3.6

148

LiHH 4×0.14

12/0.12

0.3

0.6

3.9

148

LiHH 5×0.14

12/0.12

0.3

0.6

4.2

148

LiHH 7×0.14

12/0.12

0.3

0.6

4.5

148

LiHH 8×0.14

12/0.12

0.3

0.6

4.8

148

LiHH 10×0.14

12/0.12

0.3

0.6

5.6

148

LiHH 12×0.14

12/0.12

0.3

0.7

6

148

LiHH 14×0.14

12/0.12

0.3

0.7

6.3

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.25

14/0.15

0.3

0.6

3.8

79.9

LiHH 3×0.25

14/0.15

0.3

0.6

4.1

79.9

LiHH 4×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHH 5×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHH 7×0.25

14/0.15

0.3

0.6

5.1

79.9

LiHH 8×0.25

14/0.15

0.3

0.6

5.5

79.9

LiHH 10×0.25

14/0.15

0.3

0.7

6.6

79.9

LiHH 12×0.25

14/0.15

0.3

0.7

6.9

79.9

LiHH 14×0.25

14/0.15

0.3

0.7

7.2

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.34

20/0.15

0.3

0.6

4

57

LiHH 3×0.34

20/0.15

0.3

0.6

4.3

57

LiHH 4×0.34

20/0.15

0.3

0.6

4.6

57

LiHH 5×0.34

20/0.15

0.3

0.6

5

57

LiHH 7×0.34

20/0.15

0.3

0.6

5.4

57

LiHH 8×0.34

20/0.15

0.3

0.6

5.8

57

LiHH 10×0.34

20/0.15

0.3

0.7

7

57

LiHH 12×0.34

20/0.15

0.3

0.7

7.3

57

LiHH 14×0.34

20/0.15

0.3

0.7

7.6

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.5

16/0.20

0.3

0.6

4.3

39

LiHH 3×0.5

16/0.20

0.3

0.6

4.6

39

LiHH 4×0.5

16/0.20

0.3

0.6

5

39

LiHH 5×0.5

16/0.20

0.3

0.6

5.4

39

LiHH 7×0.5

16/0.20

0.3

0.6

5.9

39

LiHH 8×0.5

16/0.20

0.3

0.7

6.5

39

LiHH 10×0.5

16/0.20

0.3

0.7

7.6

39

LiHH 12×0.5

16/0.20

0.3

0.7

7.9

39

LiHH 14×0.5

16/0.20

0.3

0.7

8.3

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.75

24/0.20

0.4

0.6

5.2

26

LiHH 3×0.75

24/0.20

0.4

0.6

5.6

26

LiHH 4×0.75

24/0.20

0.4

0.6

6.1

26

LiHH 5×0.75

24/0.20

0.4

0.7

6.6

26

LiHH 7×0.75

24/0.20

0.4

0.7

7.2

26

LiHH 8×0.75

24/0.20

0.4

0.7

8

26

LiHH 10×0.75

24/0.20

0.4

0.8

9.6

26

LiHH 12×0.75

24/0.20

0.4

0.8

10

26

LiHH 14×0.75

24/0.20

0.4

0.9

10.7

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.0

32/0.20

0.5

0.6

5.8

19.5

LiHH 3×1.0

32/0.20

0.5

0.6

6.3

19.5

LiHH 4×1.0

32/0.20

0.5

0.7

7

19.5

LiHH 5×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHH 7×1.0

32/0.20

0.5

0.9

8.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.5

30/0.25

0.5

0.6

6.4

13.3

LiHH 3×1.5

30/0.25

0.5

0.7

7.1

13.3

LiHH 4×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHH 5×1.5

30/0.25

0.5

0.8

8.6

13.3

LiHH 7×1.5

30/0.25

0.5

1.0

9.6

13.3


Product detail pictures:

Low Price For Speaker Cable - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures

Low Price For Speaker Cable - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures


Related Product Guide:

We not only will try our greatest to present fantastic expert services to each purchaser, but also are ready to receive any suggestion offered by our prospects for Low Price For Speaker Cable - LiHH Multicore Control Cable (Halogen Free) – AIPU , The product will supply to all over the world, such as: Portugal, Sheffield, Peru, For anyone who is keen on any of our items right after you view our product list, you should definitely feel absolutely free to get in touch with us for inquiries. You are able to send us emails and contact us for consultation and we shall respond to you as soon as we can. If it's easy, you may locate out our address in our web-site and come to our business for far more information of our merchandise by your self. We're always ready to construct extended and steady co-operation relations with any possible customers in the related fields.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Beatrice from Costa Rica - 2017.03.08 14:45
    Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Nancy from Liverpool - 2018.06.05 13:10
    Write your message here and send it to us