Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
We now have several exceptional workers customers good at marketing, QC, and working with types of troublesome trouble during the creation system for Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: European, Durban, Oman, We have now 48 provincial agencies in the country. We also have stable cooperation with several international trading companies. They place order with us and export solutions to other countries. We expect to cooperate with you to develop a larger market.
By Helen from Provence - 2018.06.03 10:17
The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
By Nina from Argentina - 2017.11.11 11:41