It adheres on the tenet "Honest, industrious, enterprising, innovative" to develop new items frequently. It regards buyers, success as its very own success. Let us produce prosperous future hand in hand for Modular Jack Keystone, Server Rack Depth, Combined Power And Data Cable, As an expert specialized within this field, we've been committed to solving any problem of high temperature protection for users.
Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.14

12/0.12

0.35

0.4

3.2

148

LiYY 3×0.14

12/0.12

0.35

0.4

3.5

148

LiYY 4×0.14

12/0.12

0.35

0.5

3.9

148

LiYY 5×0.14

12/0.12

0.35

0.5

4.3

148

LiYY 7×0.14

12/0.12

0.35

0.6

4.8

148

LiYY 8×0.14

12/0.12

0.35

0.6

5.2

148

LiYY 10×0.14

12/0.12

0.35

0.7

6.2

148

LiYY 12×0.14

12/0.12

0.35

0.7

6.5

148

LiYY 14×0.14

12/0.12

0.35

0.7

6.7

148

0.25mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY 3×0.25

14/0.15

0.4

0.4

3.9

79.9

LiYY 4×0.25

14/0.15

0.4

0.5

4.4

79.9

LiYY 5×0.25

14/0.15

0.4

0.5

4.8

79.9

LiYY 7×0.25

14/0.15

0.4

0.6

5.4

79.9

LiYY 8×0.25

14/0.15

0.4

0.6

5.8

79.9

LiYY 10×0.25

14/0.15

0.4

0.7

7

79.9

LiYY 12×0.25

14/0.15

0.4

0.7

7.3

79.9

LiYY 14×0.25

14/0.15

0.4

0.7

7.6

79.9

0.34mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.34

20/0.15

0.4

0.5

4.2

57

LiYY 3×0.34

20/0.15

0.4

0.5

4.5

57

LiYY 4×0.34

20/0.15

0.4

0.6

5.1

57

LiYY 5×0.34

20/0.15

0.4

0.6

5.5

57

LiYY 7×0.34

20/0.15

0.4

0.7

6.2

57

LiYY 8×0.34

20/0.15

0.4

0.7

6.7

57

LiYY 10×0.34

20/0.15

0.4

0.8

8

57

LiYY 12×0.34

20/0.15

0.4

0.8

8.3

57

LiYY 14×0.34

20/0.15

0.4

0.8

8.7

57

0.50mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.5

16/0.20

0.45

0.6

4.8

39

LiYY 3×0.5

16/0.20

0.45

0.6

5.2

39

LiYY 4×0.5

16/0.20

0.45

0.6

5.6

39

LiYY 5×0.5

16/0.20

0.45

0.6

6.1

39

LiYY 7×0.5

16/0.20

0.45

0.6

6.6

39

LiYY 8×0.5

16/0.20

0.45

0.7

7.4

39

LiYY 10×0.5

16/0.20

0.45

0.7

8.6

39

LiYY 12×0.5

16/0.20

0.45

0.8

9.2

39

LiYY 14×0.5

16/0.20

0.45

0.9

9.8

39

0.75mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.75

24/0.20

0.5

0.6

5.4

26

LiYY 3×0.75

24/0.20

0.5

0.6

5.8

26

LiYY 4×0.75

24/0.20

0.5

0.6

6.3

26

LiYY 5×0.75

24/0.20

0.5

0.7

7.1

26

LiYY 7×0.75

24/0.20

0.5

0.7

7.7

26

LiYY 8×0.75

24/0.20

0.5

0.8

8.6

26

LiYY 10×0.75

24/0.20

0.5

0.8

10

26

LiYY 12×0.75

24/0.20

0.5

0.9

10.6

26

LiYY 14×0.75

24/0.20

0.5

1

11.3

26

1.0mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY 3×1.0

32/0.20

0.6

0.6

6.7

19.5

LiYY 4×1.0

32/0.20

0.6

0.7

7.5

19.5

LiYY 5×1.0

32/0.20

0.6

0.7

8.2

19.5

LiYY 7×1.0

32/0.20

0.6

0.8

9.1

19.5

1.5mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY 3×1.5

30/0.25

0.6

0.7

7.6

13.3

LiYY 4×1.5

30/0.25

0.6

0.7

8.2

13.3

LiYY 5×1.5

30/0.25

0.6

0.8

9.2

13.3

LiYY 7×1.5

30/0.25

0.6

0.9

10.5

13.3


Product detail pictures:

Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures

Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" would be the persistent conception of our corporation to the long-term to establish collectively with customers for mutual reciprocity and mutual benefit for Leading Manufacturer For Fire Rated Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Zimbabwe, Haiti, Albania, Our company covers an area of 20, 000 square meters. We have more than 200 workers, professional technical team, 15 years' experience, exquisite workmanship, stable and reliable quality, competitive price and sufficient production capacity, this is how we make our customers stronger. If you have any inquiry, please do not hesitate to contact us.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Lulu from French - 2017.06.22 12:49
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Mary from Swiss - 2017.11.20 15:58
    Write your message here and send it to us