Good Wholesale Vendors Instrument Patch Cables - CY Screened Multicore Control Cable – AIPU
Good Wholesale Vendors Instrument Patch Cables - CY Screened Multicore Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC/LSZH
3. Identification:
Black Cores with White Number
1pc Green/Yellow Core
4. Screen: Tinned Copper Wire Braided
5. Sheath: PVC/LSZH (Grey)
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Rated Voltage: 300/300V
Reference Standards
BS6500
BS EN 60228
BS EN 50525-2-11
BS EN 50363-3
BS EN 50363-7
BS EN 50363-4-1
BS EN 50363-8
RoHS Directives
IEC60332-1
0.5mm2
|
Part No. |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.6 |
39 |
|
CY 3×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.9 |
39 |
|
CY 4×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
39 |
|
CY 5×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
39 |
|
CY 7×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
39 |
|
CY 8×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
8 |
39 |
|
CY 10×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
0.6 |
39 |
|
CY 12×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
9.9 |
39 |
|
CY 16×0.5 |
16/0.20 |
0.4 |
1.1 |
TC Braided |
11 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6 |
26 |
|
CY 3×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
26 |
|
CY 4×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
26 |
|
CY 5×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
7.33 |
26 |
|
CY 7×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
26 |
|
CY 8×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
26 |
|
CY 10×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
10.2 |
26 |
|
CY 12×0.75 |
24/0.20 |
0.4 |
1 |
TC Braided |
10.8 |
26 |
|
CY 16×0.75 |
24/0.20 |
0.4 |
1.1 |
TC Braided |
12 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.4 |
19.5 |
|
CY 3×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
19.5 |
|
CY 4×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
19.5 |
|
CY 5×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
19.5 |
|
CY 7×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
19.5 |
|
CY 8×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
9.8 |
19.5 |
|
CY 10×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
11.2 |
19.5 |
|
CY 12×1.0 |
32/0.20 |
0.4 |
1.1 |
TC Braided |
11.7 |
19.5 |
|
CY 16×1.0 |
32/0.20 |
0.4 |
1.2 |
TC Braided |
13.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7 |
13.3 |
|
CY 3×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7.4 |
13.3 |
|
CY 4×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
8.2 |
13.3 |
|
CY 5×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
9.1 |
13.3 |
|
CY 7×1.5 |
30/0.25 |
0.4 |
1 |
TC Braided |
10 |
13.3 |
|
CY 8×1.5 |
30/0.25 |
0.4 |
1.1 |
TC Braided |
11 |
13.3 |
|
CY 10×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
12.8 |
13.3 |
|
CY 12×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
13.2 |
13.3 |
|
CY 16×1.5 |
30/0.25 |
0.4 |
1.3 |
TC Braided |
14.7 |
13.3 |
2.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 2×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
8.2 |
7.98 |
|
CY 3×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
9.1 |
7.98 |
|
CY 4×2.5 |
48/0.25 |
0.5 |
1 |
TC Braided |
10.1 |
7.98 |
|
CY 5×2.5 |
48/0.25 |
0.5 |
1.1 |
TC Braided |
11.1 |
7.98 |
|
CY 7×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.2 |
7.98 |
|
CY 8×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.8 |
7.98 |
|
CY 10×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15 |
7.98 |
|
CY 12×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15.6 |
7.98 |
|
CY 16×2.5 |
48/0.25 |
0.5 |
1.4 |
TC Braided |
17.3 |
7.98 |
4.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
|
CY 3×4.0 |
56/0.30 |
0.6 |
1.1 |
TC Braided |
11.4 |
4.95 |
|
CY 4×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
12.4 |
4.95 |
|
CY 5×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
13.5 |
4.95 |
|
CY 7×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
14.8 |
4.95 |
|
CY 8×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
16.0 |
4.95 |
Product detail pictures:
Related Product Guide:
The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for Good Wholesale Vendors Instrument Patch Cables - CY Screened Multicore Control Cable – AIPU , The product will supply to all over the world, such as: Italy, Bulgaria, UK, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.