Factory Outlets Multi Core Wire Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Factory Outlets Multi Core Wire Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:


Related Product Guide:
abide by the contract", conforms to the market requirement, joins in the market competition by its high quality as well as provides more comprehensive and excellent service for clients to let them become big winner. The pursue of the company, is the clients' satisfaction for Factory Outlets Multi Core Wire Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Czech, Hyderabad, Swansea, So far our merchandise have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have now 13years experienced sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to provide our customers with high quality items and excellent service.

Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.