Constructions
1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR at |
|
LiYcY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.7 |
4.4 |
148 |
|
LiYcY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.1 |
148 |
|
LiYcY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.8 |
6.7 |
148 |
|
LiYcY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.8 |
7.2 |
148 |
|
LiYcY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.3 |
148 |
|
LiYcY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
9.4 |
148 |
|
LiYcY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10.8 |
148 |
|
LiYcY TP 12x2x0.14 |
12/0.12 |
0.35 |
1.0 |
11.4 |
148 |
0.25mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.7 |
4.8 |
79.9 |
|
LiYcY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.8 |
7 |
79.9 |
|
LiYcY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.8 |
7.4 |
79.9 |
|
LiYcY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8 |
79.9 |
|
LiYcY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.6 |
79.9 |
|
LiYcY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.9 |
10.8 |
79.9 |
|
LiYcY TP 10x2x0.25 |
14/0.15 |
0.4 |
1.0 |
12.3 |
79.9 |
|
LiYcY TP 12x2x0.25 |
14/0.15 |
0.4 |
1.1 |
12.6 |
79.9 |
0.34mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.7 |
5.2 |
57 |
|
LiYcY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.8 |
7.7 |
57 |
|
LiYcY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.8 |
8.2 |
57 |
|
LiYcY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.8 |
9 |
57 |
|
LiYcY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10.8 |
57 |
|
LiYcY TP 8x2x0.34 |
20/0.15 |
0.4 |
1.0 |
12.2 |
57 |
|
LiYcY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
|
LiYcY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.7 |
57 |
0.50mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.7 |
5.6 |
39 |
|
LiYcY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.8 |
8.3 |
39 |
|
LiYcY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9.1 |
39 |
|
LiYcY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.9 |
10 |
39 |
|
LiYcY TP 6x2x0.5 |
16/0.20 |
0.45 |
1.0 |
12 |
39 |
|
LiYcY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
13.1 |
39 |
|
LiYcY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15.5 |
39 |
0.75mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.8 |
6.4 |
26 |
|
LiYcY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.6 |
26 |
|
LiYcY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.5 |
26 |
|
LiYcY TP 4x2x0.75 |
24/0.20 |
0.5 |
1.0 |
11.4 |
26 |
|
LiYcY TP 6x2x0.75 |
24/0.20 |
0.5 |
1.1 |
13.7 |
26 |
|
LiYcY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.2 |
15 |
26 |
|
LiYcY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.7 |
26 |
1.0mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.8 |
7.2 |
19.5 |
|
LiYcY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
11.1 |
19.5 |
|
LiYcY TP 3x2x1.0 |
32/0.20 |
0.6 |
1.0 |
12.2 |
19.5 |
|
LiYcY TP 4x2x1.0 |
32/0.20 |
0.6 |
1.0 |
13.1 |
19.5 |
|
LiYcY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15 |
19.5 |
|
LiYcY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
17.4 |
19.5 |
1.5mm2
|
No. of Pairs |
Conductor |
Insulation |
Sheath |
Overall |
Max. DCR |
|
LiYcY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.8 |
7.8 |
13.3 |
|
LiYcY TP 2x2x1.5 |
30/0.25 |
0.6 |
1.0 |
12.3 |
13.3 |
|
LiYcY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
13.5 |
13.3 |
|
LiYcY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
14.7 |
13.3 |
Product detail pictures:
Related Product Guide:
Our staff through skilled training. Skilled skilled knowledge, potent sense of company, to satisfy the provider requirements of consumers for Factory Outlets For Bs6500 Cable - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: Norwegian, New Orleans, Zurich, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!