We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for Cat5e Cable, Broadband Data Cable, Gigabyte Rack Server, We are very proud of the good reputation from our customers for our products' reliable quality.
Europe Style For Excel Data Cable - LiYY TP Multipair Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.14

12/0.12

0.35

0.4

3.2

148

LiYY TP 2x2x0.14

12/0.12

0.35

0.6

5.3

148

LiYY TP 3x2x0.14

12/0.12

0.35

0.6

5.7

148

LiYY TP 4x2x0.14

12/0.12

0.35

0.7

6.4

148

LiYY TP 6x2x0.14

12/0.12

0.35

0.7

7.5

148

LiYY TP 8x2x0.14

12/0.12

0.35

0.8

8.6

148

LiYY TP 10x2x0.14

12/0.12

0.35

0.9

10

148

LiYY TP 12x2x0.14

12/0.12

0.35

1

10.4

148

LiYY TP 15x2x0.14

12/0.12

0.35

1.1

11.6

148

0.25mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY TP 2x2x0.25

14/0.15

0.4

0.6

6

79.9

LiYY TP 3x2x0.25

14/0.15

0.4

0.6

6.4

79.9

LiYY TP 4x2x0.25

14/0.15

0.4

0.7

7.2

79.9

LiYY TP 6x2x0.25

14/0.15

0.4

0.8

8.8

79.9

LiYY TP 8x2x0.25

14/0.15

0.4

0.8

9.8

79.9

LiYY TP 10x2x0.25

14/0.15

0.4

1

11.5

79.9

LiYY TP 12x2x0.25

14/0.15

0.4

1

12.1

79.9

LiYY TP 15x2x0.25

14/0.15

0.4

1.1

13.5

79.9

0.34mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.34

20/0.15

0.4

0.5

4.2

57

LiYY TP 2x2x0.34

20/0.15

0.4

0.6

6.7

57

LiYY TP 3x2x0.34

20/0.15

0.4

0.6

7.2

57

LiYY TP 4x2x0.34

20/0.15

0.4

0.7

8

57

LiYY TP 6x2x0.34

20/0.15

0.4

0.9

10

57

LiYY TP 8x2x0.34

20/0.15

0.4

1

11.4

57

LiYY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYY TP 12x2x0.34

20/0.15

0.4

1.1

13.4

57

LiYY TP 15x2x0.34

20/0.15

0.4

1.2

14.9

57

0.50mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.5

16/0.20

0.45

0.6

4.8

39

LiYY TP 2x2x0.5

16/0.20

0.45

0.7

7.5

39

LiYY TP 3x2x0.5

16/0.20

0.45

0.7

8.1

39

LiYY TP 4x2x0.5

16/0.20

0.45

0.8

9

39

LiYY TP 6x2x0.5

16/0.20

0.45

1

11.2

39

LiYY TP 8x2x0.5

16/0.20

0.45

1.1

12.8

39

LiYY TP 10x2x0.5

16/0.20

0.45

1.2

14.7

39

LiYY TP 12x2x0.5

16/0.20

0.45

1.2

15

39

LiYY TP 15x2x0.5

16/0.20

0.45

1.3

16.7

39

0.75mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.75

24/0.20

0.5

0.6

5.4

26

LiYY TP 2x2x0.75

24/0.20

0.5

0.7

8.6

26

LiYY TP 3x2x0.75

24/0.20

0.5

0.8

9.5

26

LiYY TP 4x2x0.75

24/0.20

0.5

0.9

10.4

26

LiYY TP 6x2x0.75

24/0.20

0.5

1

12.7

26

LiYY TP 8x2x0.75

24/0.20

0.5

1.1

14.5

26

LiYY TP 10x2x0.75

24/0.20

0.5

1.2

16.7

26

LiYY TP 12x2x0.75

24/0.20

0.5

1.3

17.6

26

LiYY TP 15x2x0.75

24/0.20

0.5

1.4

19.6

26

1.0mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY TP 2x2x1.0

32/0.20

0.6

0.9

10.3

19.5

LiYY TP 3x2x1.0

32/0.20

0.6

1

11.4

19.5

LiYY TP 4x2x1.0

32/0.20

0.6

1

12.3

19.5

LiYY TP 6x2x1.0

32/0.20

0.6

1.2

15.2

19.5

LiYY TP 8x2x1.0

32/0.20

0.6

1.3

16.6

19.5

LiYY TP 10x2x1.0

32/0.20

0.6

1.4

19.8

19.5

1.5mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY TP 2x2x1.5

30/0.25

0.6

1

11.5

13.3

LiYY TP 3x2x1.5

30/0.25

0.6

1.1

12.7

13.3

LiYY TP 4x2x1.5

30/0.25

0.6

1.2

13.9

13.3

LiYY TP 6x2x1.5

30/0.25

0.6

1.3

16.9

13.3

LiYY TP 8x2x1.5

30/0.25

0.6

1.3

18.3

13.3


Product detail pictures:

Europe Style For Excel Data Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures

Europe Style For Excel Data Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Europe Style For Excel Data Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Malaysia, Salt Lake City, Algeria, To get more information about us as well as see all our products, please visit our website. To get more information please feel free to let us know. Thank you very much and wish your business always be great!
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By EliecerJimenez from Liverpool - 2018.09.08 17:09
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Edwina from Bangalore - 2017.03.28 16:34
    Write your message here and send it to us