Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.3 |
148 |
LiYY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.7 |
148 |
LiYY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.4 |
148 |
LiYY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.7 |
7.5 |
148 |
LiYY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.6 |
148 |
LiYY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10 |
148 |
LiYY TP 12x2x0.14 |
12/0.12 |
0.35 |
1 |
10.4 |
148 |
LiYY TP 15x2x0.14 |
12/0.12 |
0.35 |
1.1 |
11.6 |
148 |
0.25mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6 |
79.9 |
LiYY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6.4 |
79.9 |
LiYY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.7 |
7.2 |
79.9 |
LiYY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8.8 |
79.9 |
LiYY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.8 |
79.9 |
LiYY TP 10x2x0.25 |
14/0.15 |
0.4 |
1 |
11.5 |
79.9 |
LiYY TP 12x2x0.25 |
14/0.15 |
0.4 |
1 |
12.1 |
79.9 |
LiYY TP 15x2x0.25 |
14/0.15 |
0.4 |
1.1 |
13.5 |
79.9 |
0.34mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.6 |
6.7 |
57 |
LiYY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.6 |
7.2 |
57 |
LiYY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.7 |
8 |
57 |
LiYY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10 |
57 |
LiYY TP 8x2x0.34 |
20/0.15 |
0.4 |
1 |
11.4 |
57 |
LiYY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
LiYY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.4 |
57 |
LiYY TP 15x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.9 |
57 |
0.50mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.7 |
7.5 |
39 |
LiYY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.7 |
8.1 |
39 |
LiYY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9 |
39 |
LiYY TP 6x2x0.5 |
16/0.20 |
0.45 |
1 |
11.2 |
39 |
LiYY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
12.8 |
39 |
LiYY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
14.7 |
39 |
LiYY TP 12x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15 |
39 |
LiYY TP 15x2x0.5 |
16/0.20 |
0.45 |
1.3 |
16.7 |
39 |
0.75mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.7 |
8.6 |
26 |
LiYY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.5 |
26 |
LiYY TP 4x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.4 |
26 |
LiYY TP 6x2x0.75 |
24/0.20 |
0.5 |
1 |
12.7 |
26 |
LiYY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.1 |
14.5 |
26 |
LiYY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.2 |
16.7 |
26 |
LiYY TP 12x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.6 |
26 |
LiYY TP 15x2x0.75 |
24/0.20 |
0.5 |
1.4 |
19.6 |
26 |
1.0mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
LiYY TP 3x2x1.0 |
32/0.20 |
0.6 |
1 |
11.4 |
19.5 |
LiYY TP 4x2x1.0 |
32/0.20 |
0.6 |
1 |
12.3 |
19.5 |
LiYY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15.2 |
19.5 |
LiYY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
16.6 |
19.5 |
LiYY TP 10x2x1.0 |
32/0.20 |
0.6 |
1.4 |
19.8 |
19.5 |
1.5mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY TP 2x2x1.5 |
30/0.25 |
0.6 |
1 |
11.5 |
13.3 |
LiYY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
12.7 |
13.3 |
LiYY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
13.9 |
13.3 |
LiYY TP 6x2x1.5 |
30/0.25 |
0.6 |
1.3 |
16.9 |
13.3 |
LiYY TP 8x2x1.5 |
30/0.25 |
0.6 |
1.3 |
18.3 |
13.3 |
Product detail pictures:


Related Product Guide:
Our business puts emphasis on the administration, the introduction of talented personnel, as well as the construction of team building, trying hard to further improve the standard and liability consciousness of staff members customers. Our enterprise successfully attained IS9001 Certification and European CE Certification of Big Discounting 4 Pair Network Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Croatia, Lebanon, Indonesia, Thus far, our item associated with printer dtg a4 may be shown in most foreign nations as well as urban centers, which are sought after simply by targeted traffic. We all highly imagine that now we have the full capacity to present you with contented merchandise. Desire to collect requests of your stuff and produce the long-term co-operation partnership. We very seriously promise:Csame top quality, better price; exact same selling price, higher quality.

In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!