8 Year Exporter Good Instrument Cables - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
8 Year Exporter Good Instrument Cables - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
|
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
|
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
|
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
|
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
|
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
|
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
|
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
|
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
|
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
|
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
|
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
|
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
|
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
|
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
|
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
|
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
|
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
|
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
|
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
|
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
|
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
|
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
|
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
|
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
|
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
|
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
|
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
|
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
|
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
|
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
|
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
|
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
|
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
|
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
|
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
|
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
|
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
|
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
|
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
|
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
|
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
|
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
|
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
|
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
|
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
|
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
|
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as the theory of "quality the basic, believe in the 1st and management the advanced" for 8 Year Exporter Good Instrument Cables - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Slovak Republic, Luxembourg, Estonia, Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us. In a word, when you choose us, you choose a perfect life. Welcome to visit our factory and welcome your order! For further inquiries, please do not hesitate to contact us.