2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
|
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
|
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
|
0.5~0.75mm2 |
300V |
2000V |
200 |
|
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
|
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
|
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
|
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
|
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
|
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
|
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
|
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
|
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
|
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
|
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
|
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
|
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
|
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
|
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
|
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
|
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
|
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
|
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
|
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
|
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
|
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
|
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
|
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
|
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
|
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
|
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
|
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
|
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
|
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
|
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
|
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
|
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
|
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
|
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
|
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
|
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
|
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
|
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
|
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
|
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
|
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
|
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
|
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
|
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
|
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
|
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
|
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
We believe in: Innovation is our soul and spirit. Quality is our life. Shopper need is our God for 2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Sheffield, Estonia, Zimbabwe, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.