1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.3 |
148 |
LiYY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.7 |
148 |
LiYY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.4 |
148 |
LiYY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.7 |
7.5 |
148 |
LiYY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.6 |
148 |
LiYY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10 |
148 |
LiYY TP 12x2x0.14 |
12/0.12 |
0.35 |
1 |
10.4 |
148 |
LiYY TP 15x2x0.14 |
12/0.12 |
0.35 |
1.1 |
11.6 |
148 |
0.25mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6 |
79.9 |
LiYY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6.4 |
79.9 |
LiYY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.7 |
7.2 |
79.9 |
LiYY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8.8 |
79.9 |
LiYY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.8 |
79.9 |
LiYY TP 10x2x0.25 |
14/0.15 |
0.4 |
1 |
11.5 |
79.9 |
LiYY TP 12x2x0.25 |
14/0.15 |
0.4 |
1 |
12.1 |
79.9 |
LiYY TP 15x2x0.25 |
14/0.15 |
0.4 |
1.1 |
13.5 |
79.9 |
0.34mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.6 |
6.7 |
57 |
LiYY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.6 |
7.2 |
57 |
LiYY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.7 |
8 |
57 |
LiYY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10 |
57 |
LiYY TP 8x2x0.34 |
20/0.15 |
0.4 |
1 |
11.4 |
57 |
LiYY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
LiYY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.4 |
57 |
LiYY TP 15x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.9 |
57 |
0.50mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.7 |
7.5 |
39 |
LiYY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.7 |
8.1 |
39 |
LiYY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9 |
39 |
LiYY TP 6x2x0.5 |
16/0.20 |
0.45 |
1 |
11.2 |
39 |
LiYY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
12.8 |
39 |
LiYY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
14.7 |
39 |
LiYY TP 12x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15 |
39 |
LiYY TP 15x2x0.5 |
16/0.20 |
0.45 |
1.3 |
16.7 |
39 |
0.75mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.7 |
8.6 |
26 |
LiYY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.5 |
26 |
LiYY TP 4x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.4 |
26 |
LiYY TP 6x2x0.75 |
24/0.20 |
0.5 |
1 |
12.7 |
26 |
LiYY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.1 |
14.5 |
26 |
LiYY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.2 |
16.7 |
26 |
LiYY TP 12x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.6 |
26 |
LiYY TP 15x2x0.75 |
24/0.20 |
0.5 |
1.4 |
19.6 |
26 |
1.0mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
LiYY TP 3x2x1.0 |
32/0.20 |
0.6 |
1 |
11.4 |
19.5 |
LiYY TP 4x2x1.0 |
32/0.20 |
0.6 |
1 |
12.3 |
19.5 |
LiYY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15.2 |
19.5 |
LiYY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
16.6 |
19.5 |
LiYY TP 10x2x1.0 |
32/0.20 |
0.6 |
1.4 |
19.8 |
19.5 |
1.5mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY TP 2x2x1.5 |
30/0.25 |
0.6 |
1 |
11.5 |
13.3 |
LiYY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
12.7 |
13.3 |
LiYY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
13.9 |
13.3 |
LiYY TP 6x2x1.5 |
30/0.25 |
0.6 |
1.3 |
16.9 |
13.3 |
LiYY TP 8x2x1.5 |
30/0.25 |
0.6 |
1.3 |
18.3 |
13.3 |
Product detail pictures:


Related Product Guide:
No matter new customer or previous client, We believe in prolonged time period and trustworthy relationship for 2021 High Quality Outdoor Data Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Uzbekistan, Finland, Malaysia, We have a good reputation for stable quality products, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with customers both at home and abroad. We expect sincere cooperation and common development!

The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.