2021 High Quality Ftp Lan Cable - LiYcY Screened Multicore Control Cable – AIPU
2021 High Quality Ftp Lan Cable - LiYcY Screened Multicore Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
0.14mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×0.14 |
12/0.12 |
0.35 |
0.7 |
4.4 |
148 |
|
LiYcY 3×0.14 |
12/0.12 |
0.35 |
0.7 |
4.7 |
148 |
|
LiYcY 4×0.14 |
12/0.12 |
0.35 |
0.7 |
4.9 |
148 |
|
LiYcY 5×0.14 |
12/0.12 |
0.35 |
0.7 |
5.3 |
148 |
|
LiYcY 7×0.14 |
12/0.12 |
0.35 |
0.7 |
5.6 |
148 |
|
LiYcY 8×0.14 |
12/0.12 |
0.35 |
0.8 |
6.2 |
148 |
|
LiYcY 10×0.14 |
12/0.12 |
0.35 |
0.8 |
7 |
148 |
|
LiYcY 12×0.14 |
12/0.12 |
0.35 |
0.8 |
7.3 |
148 |
|
LiYcY 14×0.14 |
12/0.12 |
0.35 |
0.8 |
7.5 |
148 |
0.25mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×0.25 |
14/0.15 |
0.4 |
0.7 |
4.8 |
79.9 |
|
LiYcY 3×0.25 |
14/0.15 |
0.4 |
0.7 |
5.1 |
79.9 |
|
LiYcY 4×0.25 |
14/0.15 |
0.4 |
0.7 |
5.4 |
79.9 |
|
LiYcY 5×0.25 |
14/0.15 |
0.4 |
0.7 |
5.8 |
79.9 |
|
LiYcY 7×0.25 |
14/0.15 |
0.4 |
0.8 |
6.4 |
79.9 |
|
LiYcY 8×0.25 |
14/0.15 |
0.4 |
0.8 |
6.8 |
79.9 |
|
LiYcY 10×0.25 |
14/0.15 |
0.4 |
0.8 |
7.8 |
79.9 |
|
LiYcY 12×0.25 |
14/0.15 |
0.4 |
0.8 |
8.1 |
79.9 |
|
LiYcY 14×0.25 |
14/0.15 |
0.4 |
0.8 |
8.2 |
79.9 |
0.34mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×0.34 |
20/0.15 |
0.4 |
0.7 |
5.2 |
57 |
|
LiYcY 3×0.34 |
20/0.15 |
0.4 |
0.7 |
5.5 |
57 |
|
LiYcY 4×0.34 |
20/0.15 |
0.4 |
0.7 |
5.9 |
57 |
|
LiYcY 5×0.34 |
20/0.15 |
0.4 |
0.7 |
6.3 |
57 |
|
LiYcY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.8 |
57 |
|
LiYcY 8×0.34 |
20/0.15 |
0.4 |
0.8 |
7.5 |
57 |
|
LiYcY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8.6 |
57 |
|
LiYcY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
9.1 |
57 |
|
LiYcY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
9.5 |
57 |
0.50mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×0.5 |
16/0.20 |
0.45 |
0.7 |
5.6 |
39 |
|
LiYcY 3×0.5 |
16/0.20 |
0.45 |
0.7 |
6 |
39 |
|
LiYcY 4×0.5 |
16/0.20 |
0.45 |
0.7 |
6.4 |
39 |
|
LiYcY 5×0.5 |
16/0.20 |
0.45 |
0.7 |
6.9 |
39 |
|
LiYcY 7×0.5 |
16/0.20 |
0.45 |
0.8 |
7.6 |
39 |
|
LiYcY 8×0.5 |
16/0.20 |
0.45 |
0.8 |
8.2 |
39 |
|
LiYcY 10×0.5 |
16/0.20 |
0.45 |
0.8 |
9.8 |
39 |
|
LiYcY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
10.2 |
39 |
|
LiYcY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
10.6 |
39 |
0.75mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×0.75 |
24/0.20 |
0.5 |
0.8 |
6.4 |
26 |
|
LiYcY 3×0.75 |
24/0.20 |
0.5 |
0.8 |
6.8 |
26 |
|
LiYcY 4×0.75 |
24/0.20 |
0.5 |
0.8 |
7.3 |
26 |
|
LiYcY 5×0.75 |
24/0.20 |
0.5 |
0.8 |
7.9 |
26 |
|
LiYcY 7×0.75 |
24/0.20 |
0.5 |
0.8 |
8.5 |
26 |
|
LiYcY 8×0.75 |
24/0.20 |
0.5 |
0.9 |
9.4 |
26 |
|
LiYcY 10×0.75 |
24/0.20 |
0.5 |
0.9 |
11 |
26 |
|
LiYcY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
11.4 |
26 |
|
LiYcY 14×0.75 |
24/0.20 |
0.5 |
1 |
12.1 |
26 |
1.0mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×1.0 |
32/0.20 |
0.6 |
0.8 |
7.2 |
19.5 |
|
LiYcY 3×1.0 |
32/0.20 |
0.6 |
0.8 |
7.7 |
19.5 |
|
LiYcY 4×1.0 |
32/0.20 |
0.6 |
0.8 |
8.3 |
19.5 |
|
LiYcY 5×1.0 |
32/0.20 |
0.6 |
0.8 |
9.2 |
19.5 |
|
LiYcY 7×1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
1.5mm2
|
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
|
LiYcY 2×1.5 |
30/0.25 |
0.6 |
0.8 |
7.8 |
13.3 |
|
LiYcY 3×1.5 |
30/0.25 |
0.6 |
0.8 |
8.4 |
13.3 |
|
LiYcY 4×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
|
LiYcY 5×1.5 |
30/0.25 |
0.6 |
0.9 |
10.2 |
13.3 |
|
LiYcY 7×1.5 |
30/0.25 |
0.6 |
1 |
11 |
13.3 |
Product detail pictures:
Related Product Guide:
We are proud of the high customer satisfaction and wide acceptance due to our persistent pursuit of high quality both on product and service for 2021 High Quality Ftp Lan Cable - LiYcY Screened Multicore Control Cable – AIPU , The product will supply to all over the world, such as: Poland, Bogota, Libya, Our R&D department always designs with new fashion ideas so we could introduce up-to-date fashion styles every month. Our strict production management systems always ensure stable and high quality products. Our trade team provides timely and efficient services. If there are any interest and inquiry about our products, please contact us in time. We would like to establish a business relationship with your honored company.
The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.